- There are only modes of transport by way of roads in the area. This includes buses as the main form of public transport and taxi as the only other option. The most common form is obviously by car.
- With the introduction of the CSELR line, some changes to the current forms of transport could be that there are less buses travelling along the same line as the light rail and more leaving from light rail stations for ease and efficiency of the public.
- The concept of interchange between forms of transport, with the inclusion of the CSELR, could be as simple as driving to the light rail station. parking your car in the car park or nearby, and joining a light rail from there. This could also be matched by catching a bus to the light rail station and changing there, and vise versa.
- From the TfNSW’s Guidelines for the Development of Public Transport Interchange Facilities, Table 4-1, p 27, these amenities and facilities are necessary. The Light rail would fall under the multi-access interchange category or the major/specialized category at peak.
1. Comfort & Convenience Facilities
| |||
Guild lines
|
Comments
| ||
1.1 Shelter
| |||
Covered links between bus stands and rail concourse
|
Continuous cover for all
|
Majority of shelter requires continuous cover except taxi.
It would be more consistent to continue the shelter out to all modes of transport in the immediate area. | |
Bus stands
|
Continuous cover for all
| ||
Taxi rank
|
Individual cover
| ||
Kiss and ride
|
Continuous cover for all
| ||
1.2 Seating
| |||
Bus stands
|
Requirement of 5 seats
|
For a multi-access category min 5 seats are required for each shelter. Although this may need to be increased as peak in the area could possibly reach major category, 10 seats.
| |
Designated waiting area
|
Requirement of 5 seats
| ||
Taxi rank
|
Requirement of 5 seats
| ||
Kiss and ride
|
Requirement of 5 seats
| ||
1.4 Ticketing (additional to rail station ticket booth and ticket machines)
| |||
Newsstand Kiosk with prepay tickets
|
Not required
|
Considered if enough available space
| |
1.5 Pay telephone
| |||
Pay telephone
|
Required at unpaid concourse and possible taxi rank.
|
Not required but would be necessary at this light rail station
| |
1.6 Toilets
| |||
Toilets
|
May be considered
|
Necessary!
| |
Baby change facilities
|
Not required
|
Possibly necessary as the population includes a lot of families.
| |
1.8 Retail
| |||
Kiosk / newsagent
|
Desirable
|
Some sort of snack will be available, variety and accessibility depending on available space
| |
Cafe
|
Where feasible
| ||
Vending machine/Food beverage
|
Desirable
| ||
1.9 Bus driver facilities
| |||
Toilets and meal room with services
|
May be required
|
A possibility since the station is the end of the line
| |
2. Information
| |||
2.1 General
| |||
Interchange name
|
required
|
All possible signage and numbering required. Including local street maps, bus routes and key destinations.
General perceptible infomation
| |
Bus platform numbering / designator
|
required
| ||
Bus stand number / designator
|
required
| ||
Interchange / station map
|
required
| ||
General bus route network
|
required
| ||
Local area street map & key destinations
|
required
| ||
2.2 Stand Specific
| |||
Stand specific bus route numbers & destination
|
Required
|
All basic information on bus routes, zones and fares
| |
Fare information & zones
|
Required
| ||
Stand specific timetables and route maps
|
Required
| ||
2.3 Real time
| |||
Route information
|
Desirable
|
More desirable information to help the public. Necessary!
| |
Next train / bus information
|
Desirable
| ||
Service disruption information
|
Desirable
| ||
3. Parking and Set-down Facilities
| |||
3.1 Car passenger drop-off and pick-up zones
|
Required
|
For a place with limited parking a drop-off place is necessary
| |
3.2 Commuter car parking
|
May be considered
|
Some parking is desired however could be hard to find the space in such a heavy populated area
| |
3.3 Bicycle parking
| |||
Bicycle Locker and / or Rack
|
Required
|
Bikes are a common form of transport so bike rack is necessary
| |
4. Safety & Security
| |||
4.1 Lighting
|
Required
|
Necessary!
| |
4.2 Video surveillance
|
Required
|
Necessary!
| |
4.3 Emergency help point
|
Desirable
|
Necessary!
| |
4.4 Public address system
|
Desirable
|
Optional
| |
Estimation of area.
2 Platforms (30x10m)
Proposed overall area of 600m^2
Concept design, including amenities, their size and location
Design including an underground carpark

- Simple and intuitive use
Use of the design is easy to understand, regardless of the user’s experience, knowledge, language skills or current concentration level.
- Size and space for approach and use
Appropriate size and space is provided for approach, reach, manipulation, and use regardless of user’s body size, posture, or mobility.
- Low physical effort
The design can be used efficiently and comfortably and with a minimum of fatigue.
- Perceptible information
The design communicates necessary information effectively to the user, regardless of ambient conditions or the user’s sensory abilities.
- Tolerance for error
The design minimizes hazards and the adverse consequences of accidental or unintended actions.
- Equitable use
The design is useful and marketable to people with diverse abilities.
- Flexibility in use
The design accommodates a wide range of individual preferences and abilities.
The most important aspect of the design is efficiency, simplicity and effectiveness.
How my design satisfies these principles
Dropbox Link for Rhino file:
https://www.dropbox.com/s/b6xvs15c70nq6wh/LightrailBitmap.3dm?dl=0
Dropbox Interim PDF:
https://www.dropbox.com/s/v9eg05tsvd20otk/ArchStudio%20Interim1.pdf?dl=0
How my design satisfies these principles
- Simple and intuitive use
Plenty of signage and easy to understand information
- Size and space for approach and use
The whole area is designed to be open, no small gaps between pillars. wheelchair and pram access from all directions.
- Low physical effort
The station is flat and steps straight out onto the park area. There are openings in all directions for easy access.
- Perceptible information
The station will have signs, monitors with information and speakers for announcements.
- Tolerance for error
There will be as little structural columns and features that could get in peoples way and cause hazards. The focus is on large open areas.
- Equitable use
With no stairs necessary the design will be marketable to many people with diverse abilities.
- Flexibility in use
There will be plenty of seating as well as standing area on the platform. There will also be a cafe and a news stand near to accommodate for individual preferences.
Images of Rhino model
Dropbox Link for Rhino file:
https://www.dropbox.com/s/b6xvs15c70nq6wh/LightrailBitmap.3dm?dl=0
Dropbox Interim PDF:
https://www.dropbox.com/s/v9eg05tsvd20otk/ArchStudio%20Interim1.pdf?dl=0








No comments:
Post a Comment